The active channel's last data screen displayed prior to turning off the instrument.
After successful channel installation, use the Magnetic Wand and repeatedly trigger <Left
Arrow> commands to leave the top level of the Installation Menu.
The display indicates data as follows (see figure below):
NOTE: The default display shows two lines of data.
First Character Field - Displays the channel number (e.g., 1 or 2).
Middle Character Field - Displays the numeric value of the data item selected.
Last Character Field - Provides a mnemonic of the data type currently displayed.
Channel Number
Selection Cursor
Although the list of available data items varies depending upon the model, the available data
usually includes those items seen in the [Flow Data] submenu of the Diagnostics Data menu.

4.10.2 SELECTING DISPLAY DATA ITEMS

The arrow keys are used to select the item that is displayed on each line as follows:
Right Arrow – Upon activating the <Right Arrow> key with the Magnetic Wand, a selection
cursor will appear under one of the channel indicator numerals (i.e., 1, 2, or 3). Activating the
<Right Arrow> once again will cause the selection cursor to move to the other display line and
so forth. (Note: The selection cursor will extinguish by itself after a period of inactivity.)
Up/Down Arrows – Once a display line is selected as described above, use the <Up or Down
Arrows> to scroll the selected display line through the available data items. (Note: On two
channel units the channel selection indicator will change when the data items come from the
other channel.)
When satisfied with the item currently displayed, stop scrolling and use the <Right Arrow> to
move to the other display line. Once the display is set up in the desired configuration, execute
no further commands and the selection cursor will eventually extinguish.
Note that the System Menu can be invoked at any time by activating the
with the Magnetic Wand.
The Data displays provided via the meter's serial interface mimic the other 1010 Family's
more elaborate graphic displays. Display selection is provided via the <Up/Down Arrows>
only. The 2 x 16 alphanumeric display is not available via the serial port.