STEP HOLD TIME ≠ KEY, FAIL CONT. = ON
9.5
1. After all steps are tested, LCD shows PASS. Please refer item 1 in section 9.3.
2. After all steps are tested, LCD shows FAIL. Please refer item 2 in section 9.3.
3. If FAIL occurred in a certain of STEP and under test. Please refer item 1 in section 9.2.
9.6

STEP HOLD TIME = KEY, FAIL CONT. = ON

1. After all steps are tested, whatever LCD shows PASS or FAIL, INTERLOCK OPEN at this
time. If START key was pressed, all STEP states are initialized and stays on STEP1
screen then the left down side of LCD shows CAN NOT TEST. By using RS232 or GPIB
interface, give [:SOURce]: SAFEty:RESult[:LAST][:JUDGment]? command to query
the judgment result, return code is 114.
2. When WAIT KEY, please refer item 2 in section 9.4.
9-2