Emerson Fisher Fieldvue DVC6030f Instruction Manual page 82

Digital valve controllers
Table of Contents

Advertisement

DVC6000f Series
Label
PARAMETER_NAME
Confirm Time
CONFIRM_TIME
Write Lock
WRITE_LOCK
Update Event
UPDATE_EVT
UNACKNOWLEDGED
5
UPDATE_STATE
TIME_STAMP
STATIC_REVISION
RELATIVE_INDEX
Block Alarm
BLOCK_ALM
UNACKNOWLEDGED
ALARM_STATE
TIME_STAMP
SUBCODE
VALUE
Alarm Summary
ALARM_SUM
CURRENT
UNACKNOWLEDGED
UNREPORTED
DISABLED
Acknowledge Option
ACK_OPTION
Write Priority
WRITE_PRI
5-16
Table 5-5. Resource Block Parameter Definitions (Continued)
Index
RO /
Mode
Number
RW
> 0
33
RW
ALL
Set by FCS
0=Undefined
34
RW
ALL
1=Unlocked
2=Locked
35
0=Undefined
35.1
RW
ALL
1=Acknowledged
2=Unacknowledged
0=Undefined
1=Update reported
35.2
RO
NA
2=Update not
reported
35.3
RO
NA
35.4
RO
NA
35.5
RO
NA
36
0=Undefined
1=Acknowledged
36.1
RW
ALL
2=Unacknowledged
0=Undefined
1=Clear reported
36.2
RO
NA
2=Clear not reported
3=Active reported
4=Active not reported
36.3
RO
NA
36.4
RO
NA
36.5
RO
NA
37
0: Discrete alarm
37.1
RO
NA
7: Block Alarm
0: Discrete alarm
37.2
RO
NA
7: Block Alarm
0: Discrete alarm
37.3
RO
NA
7: Block Alarm
0: Discrete alarm
37.4
RW
ALL
7: Block Alarm
0: Discrete Alarm
38
RW
ALL
(Write Lock off)
7: Block Alarm
39
RW
ALL
0 to 15
−Continued−
Initial
Range
Value
Data Type: Unsigned32
The time (in 1/32 millisecond) the device waits
640000
for confirmation of receipt of an alert report
before trying again.
Data Type: Unsigned8
If set to Locked, no writes from anywhere are
allowed except to clear WRITE_LOCK by
entering Unlocked. Block inputs will continue to
1=Unlocked
be updated if they are subscribers. The feature
Soft Write Lock must be selected to enable
writing to this parameter (see Device Features
in this section).
Data Type: DS-73
This alert is generated by any change to the
0=Undefined
static data. To support tracking changes in
static parameter values, the blocks static
revision parameter will be incremented each
time a static parameter value is changed. Also,
the blocks static revision parameter may be
0=Undefined
incremented if a static parameter is written but
the value is not changed. If the Actual Mode is
not Out of Service and Reports is selected in
the Feature Select parameter, then this
0
parameter will be sent to the host system
providing the host has set up alert
0
communications. Changes to static data while
the block is Out of Service will be reported
0
when the block transitions to another mode.
Data Type: DS-72
0=Undefined
This alarm is generated by a nonzero value in
the Block Error. parameter. This alarm has a
fixed priority of 2. For a BLOCK_ALM to be
broadcast to the host the following conditions
0=Undefined
must be met:
The feature Reports must be selected
Alert communication with the host must be
0
setup
In the ALARM_SUM parameter, the disable
0
bit for Block Alarm must be clear.
0
All bits: 0
Data Type: DS-74
0=clear, acknowledged, reported, enabled
All bits: 0
Current alert status, unacknowledged states,
unreported states, and disabled states of the
All bits: 0
alarms associated with the function block. The
Resource block only has two alarms: Write
Alarm and Block Alarm.
All bits: 0
Data Type: Bit String
0=Disable
0: 0
1=Enable
7: 0
Selection of whether alarms associated with
the block will be automatically acknowledged.
Data Type: Unsigned8
0
Priority of the alarm generated by setting
WRITE_LOCK to Unlocked.
Description