DVC6000f Series
375 Field Communicator Menu Structure
INPUT SELECTOR FUNCTION BLOCK
Quick Config
Alert Key
Min Good
Output Range: EU at 100%
Output Range: EU at 0%
Output Range: Units Index
Output Range: Decimal
Select Type
Common Config
Min Good
Block Mode: Target
Block Mode: Actual
Block Mode: Permitted
Block Mode: Normal
Output Range: EU at 100%
Output Range: EU at 0%
5
Output Range: Units Index
Output Range: Decimal
Select Type
Advanced Config
Alert Key
Static Revision
Status Options
Strategy
Connectors
Disable Analog Input 1: Status
Disable Analog Input 1: Value
Disable Analog Input 2: Status
Disable Analog Input 2: Value
Disable Analog Input 3: Status
Disable Analog Input 3: Value
Disable Analog Input 4: Status
Disable Analog Input 4 : Value
Input 1: Status
Input 1: Value
Input 2: Status
Input 2: Value
Input 3: Status
Input 3: Value
Input 4: Status
Input 4: Value
Operator Select: Status
Operator Select: Value
Output: Status
Output: Value
Selected: Status
Selected: Value
5-112
Online
All
Block Error
Disable Analog Input 1: Status
Disable Analog Input 1: Value
Disable Analog Input 2: Status
Disable Analog Input 2: Value
Disable Analog Input 3: Status
Disable Analog Input 3: Value
Disable Analog Input 4: Status
Disable Analog Input 4: Value
Input 1: Status
Input 1: Value
Input 2: Status
Input 2: Value
Input 3: Status
Input 3: Value
Input 4: Status
Input 4: Value
Block Mode: Target
Block Mode: Actual
Block Mode: Permitted
Block Mode: Normal
Operator Selected: Status
Operator Selected: Value
Output: Status
Output: Value
Selected: Status
Selected: Value
Status
Block Error
Characteristics
All continued
Static Revision
Alarm Summary: Current
Tag Description
Alarm Summary: Unacknowledged
Strategy
Alarm Summary: Unreported
Alert Key
Alarm Summary: Disabled
Block Mode: Target
Acknowledge Option
Block Mode: Actual
Alarm Hysteresis
Block Mode: Permitted
High High Priority
Block Mode: Normal
High High Limit
Block Error
High Priority
Output: Status
High Limit
Output: Value
Low Priority
Output Range: EU at 100%
Low Limit
Output Range: EU at 0%
Low Low Priority
Output Range: Units Index
Low Low Limit
Output Range: Decimal
High High Alarm: Unacknowledged
Grant Deny: Grant
High High Alarm: Alarm State
Grant Deny: Deny
High High Alarm: Time Stamp
Status Options
High High Alarm: Subcode
Input 1: Status
High High Alarm: Float Value
Input 1: Value
High Alarm: Unacknowledged
Input 2: Status
High Alarm: Alarm State
Input 2: Value
High High Alarm: Time Stamp
Input 3: Status
High Alarm: Subcode
Input 3: Value
High Alarm: Float Value
Input 4: Status
Low Alarm: Unacknowledged
Input 4: Value
Low Alarm: Alarm State
Disable Analog Input 1: Status
Low Alarm: Time Stamp
Disable Analog Input 1: Value
Low Alarm: Subcode
Disable Analog Input 2: Status
Low Alarm: Float Value
Disable Analog Input 2: Value
Low Low Alarm: Unacknowledged
Disable Analog Input 3: Status
Low Low Alarm: Alarm State
Disable Analog Input 3: Value
Low Low Alarm: Time Stamp
Disable Analog Input 4: Status
Low Low Alarm: Subcode
Disable Analog Input 4: Value
Low Low Alarm: Float Value
Select Type
Alarm Output: Status
Min Good
Alarm Output: Value
Selected: Status
Alarm Select
Selected: Value
Operator Select: Status
Operator Select: Value
Update Event: Unacknowledged
Update Event: Update State
Update Event: Time Stamp
Update Event: Static Rev
Update Event: Relative Index
Block Alarm: Unacknowledged
Block Alarm: Alarm State
Block Alarm: Time Stamp
Block Alarm: Subcode
Block Alarm: Value
Analog Input 5: Status
Analog Input 5: Value
Analog Input 6: Status
Analog Input 6: Value
Analog Input 7: Status
Analog Input 7: Value
Analog Input 8: Status
Analog Input 8: Value
Disable Analog Input 5: Status
Disable Analog Input 5: Value
Disable Analog Input 6: Status
Disable Analog Input 6: Value
Disable Analog Input 7: Status
Disable Analog Input 7: Value
Disable Analog Input 8: Status
Disable Analog Input 8: Value
Number Used to average