10-164
The user--specific images are stored in directories (icoxxx) in the following sub--
directories:
Manufacturer: \oem\sinumerik\hmi\ico\icoxxx
S
S
User: \oem\sinumerik\hmi\ico\icoxxx
The cross--channel status display is allocated and configured with user symbols
in the HEADER.INI file.
The HEADER.INI file is located in the directory F:\HMI_ADV and must be
copied either to the directory F:\OEM or F:\USER.
In the section UserIcons of the HEADER.INI file, enter the names of the user
symbols and the signal for the control of the symbol selection.
Note
If you have already made these entries for HMI Advanced, you do not need to
make them again for ShopTurn.
[User icons]
UI_0= <Icons_00.bmp>, <Position>
UI_0:
Icons_00.bmp:
Position:
...
UI_31= <Icons_31.bmp>, <Position>
USER_ICON_BASE = DBx.DBBy
DBx.DBBy:
The user icons are addressed bit by bit, i.e. if bit n is set in signal DBx.DBBy,
then the user icon with identifier UI_n is displayed.
If the bit is reset by the PLC, the associated user icon is deleted in the program
status display.
If several user symbols are assigned to the same position, the user symbol with
the highest identifier number is displayed.
You do not need to specify blank positions.
Additional information can be found in
References:
/IAM/, Commissioning Manual CNC Part 2 (HMI),
SINUMERIK 840D sl Commissioning Manual CNC: ShopTurn - - 11/2006 Edition
Identifier
Name of the user icon
Position for display (1 to 16)
Signal defined by user for controlling icon
selection