Signals From Shopturn (Output Signals) - Siemens SINUMERIK 840D sl Commissioning Manual

Cnc: shopturn
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

6 Signal Description
6.3
Overview of earlier ShopTurn interface
Table 6-1
Signals to ShopTurn (input signals)
Address
DB82
DBX
11.4
CMM_IN.select_spindle_readout_1
Select spindle speed display, bit 1
11.5
CMM_IN.drf_request
Select the function DRF
6.3.2

Signals from ShopTurn (output signals)

Table 6-2
Signals from ShopTurn (output signals)
Address
DB82
DBX
30.0
CMM_OUT.base_sig.main_mode_mill.manual
ShopTurn operating mode – manual
30.1
CMM_OUT.base_sig.main_mode_mill.auto -
matic
ShopTurn operating mode – automatic
32.0
CMM_OUT.base_sig.reset
Reset performed
32.1
CMM_OUT.base_sig.nc_cycle_activ
Cycle active
32.2
CMM_OUT.base_sig.nc_cycle_activ
Cycle interrupted
34.0
CMM_OUT.sub_mode_mill.tool
Operating area – Tool is selected
34.1
CMM_OUT.sub_mode_mill.directory
Operating area – Directory is selected
34.2
CMM_OUT.sub_mode_mill.messages
Operating area – Alarms/messages is
selected
34.3
CMM_OUT.sub_mode_mill.program
Operating area – Program is selected
34.7
CMM_OUT.sub_mode_mill.mda
Operating area – MDA is selected
36.0
CMM_OUT.cmm_plc_activ
ShopTurn PLC active
36.1
CMM_OUT.cmm_mmc_activ
ShopTurn operator interface active
36.7
CMM_OUT.ext_prog_sel
External processing program is selected
6-38
Name
Comments
Name
Comments
SINUMERIK 840D sl Commissioning Manual CNC: ShopTurn – 11/2006 Edition
Spares
DB31ff.DBX56.1
All bits 0: The main spindle rule applies
More than 1 bit active: The following sequence
applies:
1. Main spindle
2. Rotating tool spindle
3. Counterspindle
MMC
–> PLC DB21.DBX24.3
PLC
–> NCK DB21.DBX0.3
Connect as in the PLC user program.
Spares
Transfer is via FC19/FC24 to the standard inter-
face DB11.DBX6.2 JOG
Transfer is via FC19/FC24 to the standard inter-
face DB11.DBX6.0 AUTO
Can be simulated with the interface signal
DB21.DBX35.7 channel status reset
Transfer is via FC19/FC24 to the standard inter-
face DB21.DBX
Transfer is via FC19/FC24 to the standard inter-
face DB21.DBX
Standard interface signal
DB19.DBB21 = 205
Standard interface signal
DB19.DBB21 = 202
Standard interface signal
DB19.DBB21 = 204
Standard interface signal
DB19.DBB21 = 203
Transfer is via FC19/FC24 to the standard inter-
face DB11.DBX6.1 MDA
Omitted because ShopTurn PLC no longer exists
ShopTurn Open (PCU 50.3):
is not evaluated
ShopTurn on NCU (HMI Embedded):
DB19.DBB21
n.a.
© Siemens AG 2006 All Rights Reserved
11/2006

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents