Maximum: This is maximum range of the Set point (Analog Tag, Normally this is an Analog
input, 20 mA, 10V DC etc.)
Minimum: This is minimum range of Set Point (Analog Tag, Normally this is an Analog input, 4
mA, 0V DC etc.)
Example: If Temperature transmitter range is 0 to 100。C, set Minimum = 0, Maximum = 100.
Reverse Scale: True/False. Define Scale direction.
Step: It is the minimum value to reflect change of mercury level.
For example: By default, Step = 0 means the Mercury level moves in Real time even with a
minor change in process value.
For example: Step = 5 means the Mercury level moves its position in Real time in steps of 5.
Value: It is used to enter a process value during design time and check mercury level position
on the PC.
Indicator only: If selected, this component is used for Read only. If it is not selected, then this
component can be used for Write/Read purpose.
Write design time value: If selected, it writes design time values instead of default values
Value Position: Define position for the value to appear during Run time. Available options
include Top left, Bottom Right, Both, Internal and None. The naming convention
is based on the orientation of the component.
Section Colors: Define bands to display Ticks and Label color accordingly based on the value
of the tag during Run time.
defined in the tag database.