Action: Enable or Disable the command
To Channel: Configure the first and last channel of the external channel to be mapped.
First: Enter first external channel details, Ex: Ext1
Last: Enter last external channel details, Ex: Ext24
From Device: Configure the slave device to be mapped,
Register: Configure the Modbus address of the slave
Connection: Select the required connection where the slave is configured.
5.9.4.3 Sample Rate
Configure the sampling rate for communication.
Ethernet: Configure the Ethernet communication sampling rate from the available options
100 msec/dot, 1 sec/dot, 2 sec/Dot, 5 sec/dot, 10 sec/dot
Timeout : Timeout for Ethernet Communication. The default timeout is 100ms
Serial: Configure the Serial communication sampling rate from the available options
100 msec/dot, 1 sec/dot, 2 sec/Dot, 5 sec/dot, 10 sec/dot
Timeout : Timeout for Serial Communication. The default timeout is 100ms
Interval between two commands : Configure the interval between two commands in serial
communication. The default time is 10 msec.
5.9.5 Email
This will allow the user to enable or disable the email function on the recorder. Once the email
function is enable then the recorder will show the required menus to configure the email server details. The
user has to configure the email server configuration as per the email server. The below picture shows the
sample configuration with email account from Gmail to send email.
Type: Select the Register type as per slave. The available options are Input and
Holding Registers
Start Address: Enter Start register address. For example 400001 as 1
Data Type: Configure the data type as per slave configuration.
Int16/Uint16/Int32_B/Int32_L, UInt32_B, UInt32_L, Float_B,
Float_L
Page 178 of 479