Danfoss FC 300 Programming Manual page 91

Hide thumbs Also See for FC 300:
Table of Contents

Advertisement

FC 300 Programming Guide
4-51 Warning Current High
Range:
par.
16-37
*
A
4-52 Warning Speed Low
Range:
0 RPM
4-53 Warning Speed High
Range:
par.
4-13
*
RPM
4-54 Warning Reference Low
Range:
-999999
*
.999
4-55 Warning Reference High
Range:
999999.
*
999
4-56 Warning Feedback Low
Range:
-999999
*
.999
Function:
[Par.
4-50
-
par.
Enter the I
16-37]
the display reads
grammed to produce a status signal on terminal 27 or 29 and
on relay output 01 or 02. Refer to the drawing in this section.
Function:
*
[0 - par. 4-13]
Enter the n
the display reads
grammed to produce a status signal on terminal 27 or 29 (FC
302 only) and on relay output 01 or 02 (FC 302 only).
Function:
[Par. 4-52 - par. 4-13] Enter the n
the display reads
grammed to produce a status signal on terminal 27 or 29 and
on relay output 01 or 02. Programme the upper signal limit of
the motor speed, n
frequency converter. Refer to the drawing in this section.
Function:
[-999999.999 - par.
Enter the lower reference limit. When the actual reference falls
4-55]
below this limit, the display indicates
puts can be programmed to produce a status signal on terminal
27 or 29 and on relay output 01 or 02.
Function:
[Par.
4-54
-
Enter the upper reference limit. When the actual reference ex-
999999.999]
ceeds this limit, the display reads Ref High. The signal outputs
can be programmed to produce a status signal on terminal 27
or 29 and on relay output 01 or 02.
Function:
[-999999.999 - par.
Enter the lower feedback limit. When the feedback falls below
4-57]
this limit, the display reads Feedb Low. The signal outputs can
be programmed to produce a status signal on terminal 27 or 29
and on relay output 01 or 02.
®
MG.33.M2.02 - VLT
is a registered Danfoss trademark
value. When the motor current exceeds this limit,
HIGH
Current High
. The signal outputs can be pro-
value. When the motor speed exceeds this limit,
LOW
Speed Low
. The signal outputs can be pro-
value. When the motor speed exceeds this limit,
HIGH
Speed High
. The signal outputs can be pro-
, within the normal working range of the
HIGH
Ref Low
2. How to Programme
. The signal out-
91