Danfoss FC 300 Programming Manual page 170

Hide thumbs Also See for FC 300:
Table of Contents

Advertisement

2. How to Programme
[4]
[5]
2
[10]
[11]
[12]
[13]
[14]
[15]
[16]
[17]
[18]
[19]
[20]
[21]
[22]
[23]
[24]
[25]
[26]
[27]
[28]
[29]
[30]
[31]
170
Select set-up 3
Select set-up 3
Select set-up 4
Select set-up 4
If the set-up is changed, it will merge with other set-up com-
mands coming from either the digital inputs or via a fieldbus.
Select preset reference 0
Select preset refer-
ence 0
Select preset reference 1
Select preset refer-
ence 1
Select preset reference 2
Select preset refer-
ence 2
Select preset refer-
Select preset reference 3
ence 3
Select preset reference 4
Select preset refer-
ence 4
Select preset reference 5
Select preset refer-
ence 5
Select preset reference 6
Select preset refer-
ence 6
Select preset reference 7
Select preset refer-
ence 7
the active preset reference is changed, it will merge with other
preset reference commands coming from either the digital in-
puts or via a fieldbus.
Select ramp 1
Select ramp 1
Select ramp 2
Select ramp 2
Select ramp 3
Select ramp 3
Select ramp 4
Select ramp 4
Run
Run
[22] - issues a start command to the frequency converter.
Run reverse
Run reverse
quency converter.
Stop
Stop
Qstop
Qstop
converter.
Dcstop
Dcstop
verter.
Coast
Coast
stop commands including the coast command stop the SLC.
Freeze output
Freeze output
quency converter.
Start timer 0
Start timer 0
description.
Start timer 1
Start timer 1
description.
Start timer 2
Start timer 2
description.
MG.33.M2.02 - VLT
[4] - changes the active set-up (par. 0-10) to '3'.
[5] - changes the active set-up (par. 0-10) to '4'.
[10] – selects preset reference 0.
[11] – selects preset reference 1.
[12] – selects preset reference 2.
[13] – selects preset reference 3.
[14] – selects preset reference 4.
[15] – selects preset reference 5.
[16] – selects preset reference 6.
[17] - selects preset reference 7. If
[18] - selects ramp 1.
[19] - selects ramp 2.
[20] - selects ramp 3.
[21] - selects ramp 4.
[23] - issues a start reverse command to the fre-
[24] - issues a stop command to the frequency converter.
[25] - issues a quick stop command to the frequency
[26] - issues a DC stop command to the frequency con-
[27] - the frequency converter coasts immediately. All
[28] - freezes the output frequency of the fre-
[29] - starts timer 0, see par. 13-20 for further
[30] - starts timer 1, see par. 13-20 for further
[31] - starts timer 2, see par. 13-20 for further
®