To Set Up Time Correlation Between Two State Analyzers; To Set Up Time Correlation Between A Timing And A State Analyzer - HP 1660CS-Series User Manual

Logic analyzers
Table of Contents

Advertisement

To set up time correlation between two state analyzers

To correlate the data between two state analyzers, both must have Count
Time turned on in their Trigger menus. Although both have Count State
available, it is not possible to correlate data based on states even when they
are identically defined.
In the Analyzer Trigger menu, select Count.
1
Count may be Count Off, Count Time, or Count States. Selecting the field
causes a pop-up to appear.
Select the field after Count: and select Time.
2
A warning may appear about reduced memory. It will not prevent you from
changing Count to Count Time.
Select Done.
3
Repeat steps 1 through 3 for the other state analyzer.
4
Now when you acquire data you will be able to interleave the listings.
To set up time correlation between a timing and a
state analyzer
To set up time correlation between a timing and a state analyzer, only the
state analyzer needs to have Count Time turned on. The timing analyzer
automatically keeps track of time.
In the state Analyzer Trigger menu, select Count.
1
Count may be Count Off, Count Time, or Count States. Selecting the field
causes a pop-up to appear.
Select the field after Count: and select Time.
2
A warning may appear about reduced memory. It will not prevent you from
changing Count to Count Time.
Select Done.
3
Now when you acquire data you will be able to set up a mixed display.
To set up time correlation between two state analyzers
Using the Trigger Menu
4–11

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

1662cs1663cs1660cs1661cs

Table of Contents