To Capture A Write Of Known Bad Data To A Particular Variable - HP 1660CS-Series User Manual

Logic analyzers
Table of Contents

Advertisement

To capture a write of known bad data to a particular variable

To capture a write of known bad data to a particular
variable
The trigger specification ANDs the bad data on the data bus, the write
transaction on the status bus, and the address of the variable on the address
bus.
Go to the state analyzer's Trigger menu.
1
Define the terms BAD_DATA, WRITE, and VAR_ADDR to represent
2
the bad data value, write status, and the address of the variable.
Under State Sequence Level 1, enter the following sequence
3
specification (use the Combination trigger term):
While storing "anystate" TRIGGER on "BAD_DATA • WRITE •
VAR_ADDR" Occurs "1" Else on "no state" go to level "1"
Capturing a bad write to a variable
Single-Machine Trigger Examples
5-11