The Analyzer Trigger Menu

State trigger macro library

Delay
1. Wait "t" seconds
This macro becomes true after a designated time period has expired. It uses
one internal sequence level.
State trigger macro library
The following list contains all the macros in the library of state trigger
macros. They are listed in the same order as they appear onscreen.
User Mode
User level - custom combinations, loops
The User level is a user-definable level. This level offers low-level
configuration and uses one internal sequence level.
Basic Macros
1. Find anystate "n" times
This macro becomes true when the first state it sees occurs "n" number of
times. It uses one internal sequence level.
2. Find event "n" times
This macro becomes true when it sees a designated pattern occurring a
designated number of times consecutively or nonconsecutively. It uses one
internal sequence level.
3. Find event "n" consecutive times
This macro becomes true when it sees a designated pattern occurring a
designated number of consecutive times. It uses one internal sequence level.
4. Find event 2 immediately after event 1
This macro becomes true when the first designated pattern is seen
immediately followed by a second designated pattern. It uses two internal
sequence levels.
Sequence
1. Find event 2 "n" times after event 1, before event 3 occurs
Dependent macros
This macro becomes true when it first finds a designated pattern 1, followed
by a selected number of occurrences of a designated pattern 2. In addition, if
a designated pattern 3 is seen anytime while the sequence is not yet true, the
sequence starts over. If pattern 2's "nth" occurrence is coincident with
pattern 3, the sequence starts over. It uses two internal sequence levels.
7-46