To Detect A Handshake Violation - HP 1660CS-Series User Manual

Logic analyzers
Table of Contents

Advertisement

Single-Machine Trigger Examples

To detect a handshake violation

To detect a handshake violation
Go to the timing analyzer's Trigger menu.
1
Define the Edge1 term to represent either transition on the first
2
handshake line, and the Edge2 term to represent either transition on
the second handshake line.
You can rename these terms to match your problem, for example, to REQ
and ACK.
Under Timing Sequence Levels, enter the following sequence
3
specification:
Find "REQ" Occurs "1" Else on "no state" go to level "1"
TRIGGER on "REQ" Occurs "1" Else on "ACK" go to level "1"
Triggering on a handshake violation