Case b):
For example, output CCO should be switched off after 200,000 count signals.
Counter Flag
Reset Enable
CCO
CPU counter
Programming
Classic:
Programming examples
manual and on the TCS Support site
xx7: the firmware reads in the values according to the configuration (I/O Builder)
Watchdog: This module cannot be used on the base address 240 (or 496 for the
PCD2.M17x), because it would interact with the watchdog, and would cause a
malfunction.
For details, please refer to the
of the watchdog in conjunction with PCD2 components.
Manual Manual PCD  1 / PCD  2 Series │  D ocument 26 / 737 EN22  │   2 013-11-26
If the count range has to extend beyond the value 65,535, "Reset
Enable" can be activated later, i.e. between the penultimate and the
last time the counter reaches zero. This means that the CCO output is
only reset after several passes of the counter. The number of passes is
counted by a CPU counter.