Troubleshooting
Bit
Hex
Alarm Word Extended Status Word
0
00000001
1
00000002
2
00000004
5
5
3
00000008
4
00000010
5
00000020
6
00000040
7
00000080
8
00000100
9
00000200
10
00000400
11
00000800
12
00001000
13
00002000
14
00004000
15
00008000
16
00010000
17
00020000
18
00040000
198
®
VLT
Dec
Alarm Word
1
Brake Check (A28)
2
Heatsink temp.
(A29)
4
Earth Fault (A14)
8
Ctrl.Card Temp
(A65)
16
Ctrl. Word TO (A17) ServiceTrip,
32
Over Current (A13)
64
Torque Limit (A12)
128
Motor Th Over
(A11)
256
Motor ETR Over
(A10)
512
Inverter Overld.
(A9)
1024
DC under Volt (A8) reserved
2048
DC over Volt (A7)
4096
Short Circuit (A16)
8192
Inrush Fault (A33)
16384
Mains ph. Loss (A4) reserved
32768
AMA Not OK
65536
Live Zero Error (A2) reserved
131072
Internal Fault (A38) KTY error
262144
Brake Overload
(A26)
MG33ME02 - VLT
AutomationDrive Programmming Guide
Alarm Word 2
Warning Word
ServiceTrip, Read/
Brake Check (W28)
Write
ServiceTrip,
Heatsink temp. (W29)
(reserved)
ServiceTrip,
Earth Fault (W14)
Typecode/
Sparepart
ServiceTrip,
Ctrl.Card Temp (W65)
(reserved)
Ctrl. Word TO (W17)
(reserved)
reserved
Over Current (W13)
reserved
Torque Limit (W12)
reserved
Motor Th Over (W11)
reserved
Motor ETR Over (W10)
reserved
Inverter Overld (W9)
DC under Volt (W8)
reserved
DC over Volt (W7)
reserved
DC Voltage Low (W6)
reserved
DC Voltage High (W5)
Mains ph. Loss (W4)
reserved
No Motor (W3)
Live Zero Error (W2)
10V Low (W1)
Fans error
Brake Overload (W26)
®
is a registered Danfoss trademark
Warning
Extended
Word 2
Status Word
reserved
Ramping
reserved
AMA Running
reserved
Start CW/CCW
start_possible is
active, when the DI
selections [12] OR
[13] are active and
the requested
direction matches the
reference sign
reserved
Slow Down
slow down command
active, e.g. via CTW
bit 11 or DI
Catch Up
catch up command
active, e.g. via CTW
bit 12 or DI
reserved
Feedback High
feedback > 4-57
reserved
Feedback Low
feedback < 4-56
reserved
Output Current High
current > 4-51
reserved
Output Current Low
current < 4-50
reserved
Output Freq High
speed > 4-53
Output Freq Low
speed < 4-52
Brake Check OK
brake test NOT ok
reserved
Braking Max
BrakePower >
BrakePowerLimit
(2-12)
Braking
Out of Speed Range
OVC Active
AC Brake
KTY Warn
Password Timelock
number of allowed
password trials
exceeded - timelock
active
Fans Warn
Password Protection
0-61 =
ALL_NO_ACCESS OR
BUS_NO_ACCESS OR
BUS_READONLY