Danfoss VLT AutomationDrive FC 300 Series Programming Manual page 181

Hide thumbs Also See for VLT AutomationDrive FC 300 Series:
Table of Contents

Advertisement

Parameter Lists
4.1.16 14-** Special Functions
Par.
Parameter description
No. #
14-0* Inverter Switching
14-00
Switching Pattern
14-01
Switching Frequency
4
4
14-03
Overmodulation
14-04
PWM Random
14-06
Dead Time Compensation
14-1* Mains On/Off
14-10
Mains Failure
14-11
Mains Voltage at Mains Fault
14-12
Function at Mains Imbalance
14-13
Mains Failure Step Factor
14-14
Kin. Backup Time Out
14-15
Kin. Backup Trip Recovery Level
14-2* Trip Reset
14-20
Reset Mode
14-21
Automatic Restart Time
14-22
Operation Mode
14-23
Typecode Setting
14-24
Trip Delay at Current Limit
14-25
Trip Delay at Torque Limit
14-26
Trip Delay at Inverter Fault
14-28
Production Settings
14-29
Service Code
14-3* Current Limit Ctrl.
14-30
Current Lim Ctrl, Proportional Gain
14-31
Current Lim Ctrl, Integration Time
14-32
Current Lim Ctrl, Filter Time
14-35
Stall Protection
14-4* Energy Optimising
14-40
VT Level
14-41
AEO Minimum Magnetisation
14-42
Minimum AEO Frequency
14-43
Motor Cosphi
14-5* Environment
14-50
RFI Filter
14-51
DC Link Compensation
14-52
Fan Control
14-53
Fan Monitor
14-55
Output Filter
14-56
Capacitance Output Filter
14-57
Inductance Output Filter
14-59
Actual Number of Inverter Units
14-7* Compatibility
14-72
Legacy Alarm Word
14-73
Legacy Warning Word
14-74
Leg. Ext. Status Word
14-8* Options
14-80
Option Supplied by External 24VDC
14-89
Option Detection
180
®
VLT
AutomationDrive Programmming Guide
Default value
null
null
[1] On
[0] Off
[1] On
[0] No function
App.Dependent
[0] Trip
1.0 N/A
60 s
App.Dependent
[0] Manual reset
App.Dependent
[0] Normal operation
null
60 s
60 s
App.Dependent
[0] No action
0 N/A
100%
0.020 s
1.0 ms
[1] Enabled
66%
App.Dependent
10 Hz
App.Dependent
[1] On
[1] On
[0] Auto
[1] Warning
[0] No Filter
App.Dependent
App.Dependent
App.Dependent
0 N/A
0 N/A
0 N/A
[1] Yes
[0] Protect Option Config.
®
MG33ME02 - VLT
is a registered Danfoss trademark
4-set-up
Change
Conver-
during
sion index
operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
2 set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
FALSE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
1 set-up
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
2 set-ups
FALSE
1 set-up
TRUE
Type
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint16
-
Uint8
-1
Uint8
0
Uint8
-3
Uint32
-
Uint8
0
Uint16
-
Uint8
-
Uint8
0
Uint8
0
Uint8
0
Uint8
-
Uint8
0
Int32
0
Uint16
-3
Uint16
-4
Uint16
-
Uint8
0
Uint8
0
Uint8
0
Uint8
-2
Uint16
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-7
Uint16
-6
Uint16
0
Uint8
0
Uint32
0
Uint32
0
Uint32
-
Uint8
-
Uint8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT AutomationDrive FC 300 Series and is the answer not in the manual?

Questions and answers

Table of Contents