Parameter Lists
4.1.14 12-** Ethernet
Par.
Parameter description
No. #
12-0* IP Settings
12-00 IP Address Assignment
12-01 IP Address
12-02 Subnet Mask
12-03 Default Gateway
12-04 DHCP Server
12-05 Lease Expires
12-06 Name Servers
12-07 Domain Name
12-08 Host Name
12-09 Physical Address
12-1* Ethernet Link Parameters
12-10 Link Status
12-11 Link Duration
12-12 Auto Negotiation
12-13 Link Speed
12-14 Link Duplex
12-2* Process Data
12-20 Control Instance
12-21 Process Data Config Write
12-22 Process Data Config Read
12-23 Process Data Config Write Size
12-24 Process Data Config Read Size
12-27 Primary Master
12-28 Store Data Values
12-29 Store Always
12-3* EtherNet/IP
12-30 Warning Parameter
12-31 Net Reference
12-32 Net Control
12-33 CIP Revision
12-34 CIP Product Code
12-35 EDS Parameter
12-37 COS Inhibit Timer
12-38 COS Filter
12-4* Modbus TCP
12-40 Status Parameter
12-41 Slave Message Count
12-42 Slave Exception Message Count
12-5* EtherCAT
12-50 Configured Station Alias
12-51 Configured Station Address
12-59 EtherCAT Status
Table 4.17
®
VLT
AutomationDrive Programmming Guide
Default value
null
2 set-ups
0 N/A
0 N/A
0 N/A
0 N/A
2 set-ups
App.Dependent
All set-ups
0 N/A
0 N/A
0 N/A
0 N/A
[0] No Link
App.Dependent
All set-ups
[1] On
2 set-ups
[0] None
2 set-ups
[1] Full Duplex
2 set-ups
App.Dependent
App.Dependent
All set-ups
App.Dependent
All set-ups
16 N/A
All set-ups
16 N/A
All set-ups
0 N/A
[0] Off
All set-ups
[0] Off
0 N/A
All set-ups
[0] Off
2 set-ups
[0] Off
2 set-ups
App.Dependent
All set-ups
App.Dependent
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
0 N/A
All set-ups
0 N/A
All set-ups
®
MG33ME02 - VLT
is a registered Danfoss trademark
4-set-up
FC 302
Change
only
during
operation
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
TRUE
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
TRUE
TRUE
TRUE
TRUE
1 set-up
TRUE
TRUE
TRUE
TRUE
TRUE
1 set-up
FALSE
TRUE
1 set-up
TRUE
TRUE
TRUE
TRUE
TRUE
1 set-up
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
1 set-up
FALSE
TRUE
TRUE
Conver-
Type
sion index
-
Uint8
0
OctStr[4]
4
0
OctStr[4]
0
OctStr[4]
0
OctStr[4]
0
TimD
0
OctStr[4]
0
VisStr[48]
0
VisStr[48]
0
VisStr[17]
-
Uint8
0
TimD
-
Uint8
-
Uint8
-
Uint8
0
Uint8
-
Uint16
-
Uint16
0
Uint32
0
Uint32
0
-
Uint8
-
Uint8
0
Uint16
-
Uint8
-
Uint8
0
Uint16
0
Uint16
0
Uint32
0
Uint16
0
Uint16
0
Uint16
0
Uint32
0
Uint32
0
Uint16
0
Uint16
0
Uint32
177
4
Need help?
Do you have a question about the VLT AutomationDrive FC 300 Series and is the answer not in the manual?
Questions and answers