Safe Data; 10.8.2.1 Data Incompatible; 10.8.2.2 Data Compatible - Pepperl+Fuchs VBG-PN-K30-DMD-S16-EV Manual

As-i 3.0 profinet gateway with integr. safety monitor
Table of Contents

Advertisement

AS-i 3.0 PROFINET Gateway with integr. Safety Monitor
Function and startup of the Safety Monitor
Description
CHIP CARD>MASTER: Chip card data are copied to the master
MASTER->CHIPCARD: Master data are copied to the chip card
The menu can be exited by pressing the ESC/Service key without changing the
data.
10.8.2

Safe data

This section describes the system behavior of the safe unit when using the chip
card.
In general the safe part of the chip card has 4 memory banks (A...D). A bank is
referred to as an active bank. Unless otherwise stated, the operations described
in the following are always performed on the active bank.

10.8.2.1 Data incompatible

If a card with incompatible data is found, the following error message is output:

10.8.2.2 Data compatible

If a card with an empty active memory bank is found, the safety configuration in-
cluding code sequences is written to the card and in future all changes are made
in the card and in the device at the same time. The following message is dis-
played on the device:
CHIPCARD AND
AS-I DATA
DIFFERENT
CARD->MASTER
MASTER->CARD
CONTINUE
NEXT: No change to the data
CHIPCARD NOT
COMPATIBLE
CHIPCARD FOUND.
SAFETY DATA WILL
BE SYNCHRONIZED
71