Pepperl+Fuchs VBG-PN-K30-DMD-S16-EV Manual page 100

As-i 3.0 profinet gateway with integr. safety monitor
Table of Contents

Advertisement

AS-i 3.0 PROFINET Gateway with integr. Safety Monitor
Configuration of AS-i/PROFINET Gateways
Coding of status bytes
0
1
The cyclical output identifier contains the 4 Safety Monitor bits 1.Y1, 1.Y2, 2.Y1
and 2.Y2. The monitoring element "Monitor input" and the start elements "Monitor
Start-Monitor Input" and "Activation using Monitor Input" access these data. In
contrast, the "Feedback circuit" element always accesses the EDM input.
Outputs
byte description
1 byte from the fieldbus
bit 4 ... 7: reserved
2 reserved
The bits of the output bytes are ORed with the real and the homonymous hard-
ware inputs of the device.
Safety Control Status
Length
2 byte I
1 byte O
4 byte I
1 byte O
6 byte I
2 byte O
8 byte I
2 byte O
10 byte I
3 byte O
12 byte I
3 byte O
14 byte I
4 byte O
16 byte I
4 byte O
100
no device flashing red
at least one device flash-
ing red
bit 0: 1.Y1
bit 1: 1.Y2
bit 2: 2.Y1
bit 3: 2.Y2
description
Safety Ctrl/Status (2 OSSD)
Safety Ctrl/Status (4 OSSD)
Safety Ctrl/Status (6 OSSD)
Safety Ctrl/Status (8 OSSD)
Safety Ctrl/Status (10 OSSD)
Safety Ctrl/Status (12 OSSD)
Safety Ctrl/Status (14 OSSD)
Safety Ctrl/Status (16 OSSD)
Tab. 13-35.
Tab. 13-36.
Tab. 13-37.