Specifications - AS-i/PROFINET Gateways
System configuration - example 2: Calculation of the system reaction time
S1-1
AS-i 1
S2-1
AS-i 2
Upon locking of the EMERGENCY-OFF switch S2-1, the motor starter is control-
led via the safe AS-interface output of safety monitor SM2-1.
Calculation of the AS-interface-relevant system reaction time:
t
= t
System total b)
System configuration - example 3: Calculation of the system reaction time
SM1-1
AS-i Safety Monitor
M
SM2-1
AS-i Safety Monitor
+ t
+ t
R S2-1
R System
R A2-1
SM1-2
AS-i Safety Monitor
M
M
M
A2-1
I –
I +
I +
I +
I 1
I 2
1.Y1
1.Y2
Run
Prg
Prg
1.13
1.14
1.23
1.24
ASI+
ASI–
nc
nc
= 100ms + 40ms + 50ms = 190ms