AS-i 3.0 PROFINET Gateway with integr. Safety Monitor
Specifications - AS-i/PROFIsafe Gateway
6.2
Safety-relevant characteristic data
Characteristic data
Safety category
Performance Level (PL)
Safety Integrity Level (SIL)
Lifespan (TM) in years
Maximum switch-on time in months
PFD
PFH
D
probability of a dangerous failure per hour
(
Max. system reaction time in milliseconds
PROFIsafe → local relay output
PROFIsafe → local electronic output
PROFIsafe → AS-i relay output
PROFIsafe → AS-i electronic output
AS-i → PROFIsafe
PROFINET → local output
PROFINET → AS-i
AS-i → local output
AS-i → AS-i
AS-i → PROFINET
Attention!
In addition to the system reaction time in the gateway, eventually reaction times of
other daisy-chained safe AS-i and PROFIsafe componentshave to be added too.
Please note that additional reaction times may likewise arise through the configuration
of the safety unit.
26
Value
4
e
3
20
12
-6
< 9,25 x 10
-9
< 5,36 x 10
)
15
5
60
50
30
40
50
Standard
EN 954-1
EN ISO 13849-1: 2008
EN ISO 13849-1: 2008
IEC 61508: 2001
EN ISO 13849-1: 2008
IEC 61508: 2001
IEC 61508: 2001,
EN 62061: 2005
IEC 61508: 2001,
EN 62061: 2005
IEC 61508: 2001
Tab. 6-7.