19.1

Startup on a Siemens NC control

The following example describes the settings needed for starting up a PROFIsafe
Gateway on a Siemens NC control (here an 840dSL).
To place the PROFIsafe Gateway in operation on a Siemens control, a few set-
tings are needed for the Gateway to function.
The individual items here are excerpted as examples from the corresponding Sie-
mens manuals.
19.1.1

Setting in the S7 configuration

Install the corresponding GSD file in the S7 hardware configuration.
Insert the Gateway into the PROFIBUS circuit (this can be found under Profi-
bus-DP, Additional field devices, Gateways, AS-i).
Set the corresponding PROFIsafe protocol (the NC control only supports V1
at the present time).
Note!
The Profisafe data field must be inserted in "Slot 1" (see illustration).
The "F_Dest_Add" is set in the PROFIsafe data field, and must then also be set in
the
NC
PROFISAFE_OUT_ADDRESS".
120
control
under
"PROFISAFE_IN_ADDRESS"
and