USING THE MACHINE
c In  the  case  of  the  electric  motor  230V  to  the  network  are  required  at  least
3.9Kw. Use to connect a cable pole least ʺ3x2.5mm2ʺ with ground socket type F47,
double insulated with plug for at least 16A. The maximum cable length must be
10 m
d In  the  case  of  the  electric  motor  110V  to  the  network  are  required  at  least
4.1Kw. Use to connect a cable pole least ʺ3x6mm2ʺ with ground socket type F47,
double insulated with plug for at least 32A. The maximum cable length must be
10 m
e Place  an  earth  plate  in  the  ground  and  connect  it  to  the  machineʹs  ground
clamp or, if this is not possible, make sure the power connection is earthed (e.g.
indoors).
• Make sure that all the emergency STOP buttons are released; this condition
can be checked on the remote control display, where no icon should appear in po‐
sition 7 ʺFig. 40 Emergency stop pressed(p. 56)ʺ. If the operator attempts to start
the machine with the emergency stop button still pressed, an error message will
appear on the display when the start button is pressed.
• Use the button on the remote control to start the motor.
• If the operator attempts to start one of the two motors while the other is alre‐
ady running, starting will be impossible and the icon showing the motor already
on will appear at the centre of the screen.
The engine must be started with all the control buttons and joysticks
in  neutral  position.  Always  make  sure  there  are  no  foreign  objects
(e.g. Branches) that may accidentally operate a control, as the pla‐
tform may move suddenly out of the operatorʹs control and cause se‐
rious harm to things and/or people. Make sure that all the manual
controls for the proportional valves are at rest.
90
Fig. 83 Error, ignition attempt with stop pressed
Boom Lift Models X17JPLUS
MUX17JP021602