External Temperature Sensor (Optional) - JLG X17JPLUS Operator, Safety, And General Maintenance Manual

Table of Contents

Advertisement

MUX17JP021602
the main circuit board an icon appears in position 7 of the remote control ʺDisplay
(p. 53)ʺ. If one or both sensors should break, contact the after sales service.
8.13.EXTERNAL TEMPERATURE SENSOR (OPTIONAL)
If the machine is approved for use in outdoor environments for the Russian mar‐
ket, the Compact Crawler Boom will be installed with a temperature sensor/cut
out.  Should the ambient temperature drop below a predetermined limit, refer to
ʺDanger due to atmospheric conditions (p. 80)ʺ, the function being operated will
stop and an audible alarm will sound.  Operators must lower the platform to the
ground, by first placing the function being operated into a neutral position and
then  selecting  controls  which  will  permit  the  platform  to  be  lowered  to  the
ground safely. Movement during this time will be at creep speed.
Should a more urgent recovery of the platform be required, for example, in
the event of a failure of the platform controls or the incapacitation of an ope‐
rator, the ground control panel may be used by trained personnel at normal
function speeds to lower the platform to the ground safely.
A visually check is required before operation of the machine to ensure
the sensor is secure and free from dirt or debris.
Do not operate a machine displaying an error code or warning.
Boom Lift Models X17JPLUS
SAFETY DEVICE