Using The Machine; Safety Standards To Adopt Before Using The Platform; Risk Of Electrocution; Danger Due To Atmospheric Conditions - JLG X17JPLUS Operator, Safety, And General Maintenance Manual

Table of Contents

Advertisement

USING THE MACHINE
11.USING THE MACHINE
11.1.SAFETY STANDARDS TO ADOPT BEFORE USING THE PLATFORM
11.1.1.Risk of electrocution
If the machine must be used near electric power lines, the user must remain at a
suitable distance from the latter. The table below supplies the values relating to
the minimum distance from electric power lines depending on the type of volta‐
ge.
SAFETY DISTANCE FROM POWER LINES
LINE RATED VOLTAGE
FROM
0 V
300 V
50 KV
200 KV
350 KV
500 KV
750 KV
Keep a safe distance from mains power lines and electrical systems,
considering the possible range of movement of the machine and its
oscillation, as well as the possible oscillation of the power lines.
Before  starting  operation,  examine  the  work  area,  taking  note  of
overhead  power  lines,  moving  machinery,  such  as  overhead  cranes
and road, rail and building equipment.
11.1.2.Danger due to atmospheric conditions
DO NOT WORK IN UNFAVOURABLE ATMOSPHERIC CONDITIONS
Do not work in the presence of storms, snow, fog or wind exceeding 12 m/s. Do
not  operate  the  machine  when  the  ambient  temperature  drops  below  ‐20°C  or
80
TO
300 V
50 KV
200 KV
350 KV
500 KV
750 KV
1000 KV
Boom Lift Models X17JPLUS
MUX17JP021602
SAFETY DISTANCE (ME‐
TRES)
5
5
5
6.1
7.6
10.7
13.7

Advertisement