Assigning Parameters To The Tcp/Ip Communication With A Control System - Siemens SINUMERIK 840D sl Commissioning Manual

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

14.9.4

Assigning parameters to the TCP/IP communication with a control system

Background
To be able to read or transfer license information from or to the CF card of a control system,
the Automation License Manager must communicate with the control system via TCP/IP.
Requirements:
● The HMI basic software is installed
● The SINUMERIK plug-in is enabled
General communication parameters
The default general communication parameters for the HMI basic software are stored in the
following initialization file:
<installation drive>:\Siemens\Sinumerik\HMI-Advanced\mmc2\MMC.INI
User-specific communication parameters
The user-specific communication parameters for the HMI basic software are stored in the
following initialization file:
<installation drive>:\Siemens\Sinumerik\HMI-Advanced\user\MMC.INI
During evaluation of the initialization data when booting the HMI basic software, user-specific
communication parameters have priority over general communication parameters.
Sections of the initialization file: MMC.INI
The parameters relevant to TCP/IP communication with SINUMERIK control systems are
stored in the following sections:
● [ GLOBAL ]
● [
Table 14-1
Statements
[GLOBAL]
NcddeMachineName =
NcddeDefaultMachineName =
NcddeMachineNames =
IBN CNC: NCK, PLC, drive
Commissioning Manual, 07/2007, 6FC5397-2AP10-3BA0
Note
HMI Advanced
If the SINUMERIK user interface "HMI Advanced" is installed on the same computer
(PC/PG) as the Automation License Manager you can set the IP address using the user
interface. The IP address for the control system with which both HMI Advanced as well as
the Automation License Manager communicate is set via the following dialog:
Operating area switchover > Start-up > HMI > NCU link
This requires at least the password of protection level 2 (manufacturer) to be set.
Section: [ GLOBAL ] specifies the section (e.g.
communication parameters for the current SINUMERIK control system.
AddressParameter
]
The name of this section can be any unique ASCII string within the file. The specified IP
address is crucial for communication with the current SINUMERIK control system:
address
.
User-specific file: MMC.INI
AddressParameter
AddressParameter
14.9 Assigning via Automation License Manager
AddressParameter
AddressParameter
Licensing
) that contains the
IP
277

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120

Table of Contents