PLC commissioning
7.1 Creating a SIMATIC S7 project
7.1.6

End hardware configuration and load to the PLC

End hardware configuration and load to the PLC
To end the overall configuration and generate the system data for the PLC, the project must
be saved and compiled.
1. Select the menu "Station > Save and compile".
2. Click on the button "Load in module", to load the configuration to the PLC.
Figure 7-12
3. Confirm with OK to load into these two modules.
4. Confirm the dialog boxes displayed subsequently with "OK" or "No" for the query
"...Should the module be started now (restart)?".
Note
You can test the communication interface at "Target system > Diagnosis > Operating
mode".
5. Close the "HW config" window.
The next step is to create the PLC program.
50
The "Select target module" dialog mask automatically displays both configured
communication partners (see figure below).
Selecting target module
Commissioning Manual, 07/2007, 6FC5397-2AP10-3BA0