Siemens SINUMERIK 840D sl Commissioning Manual page 255

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Table 13-2
Component
1) Not active
2) End of exchange of PZD
Procedure for assigning the drive objects in parameter p978
You are now in the "Commissioning > Machine data > Control Unit MD" menu.
p978 can be written using the following sequence:
1. Set p9 = 1
2. Set p978 [0...9] to the values outlined in the table below (column ...List of drive
3. Set p9 = 0
4. Save "All": set p977 = 1
See also
Overview - Assignment of SINAMICS and NCK machine data for communication via
PROFIBUS (Page 251)
IBN CNC: NCK, PLC, drive
Commissioning Manual, 07/2007, 6FC5397-2AP10-3BA0
Assignment p978[0...9] for infeed without DRIVE-CLiQ connection
1. Motor module
2. Motor module
3. Motor module
not found
not found
not found
CU
ALM, only if protocol 370 is
available
not found
not found
objects...), e.g., 3-4-5-255-255-255-1-255-0-2.
– Motor Module drive objects, ascending order (connected as per DRIVE-CLiQ)
– Control unit
– ALM
It is imperative you wait until p977 is automatically written back to "0".
13.9 Drive-object assignment for PROFIBUS connection
Index p978
List of drive objects
0
1
2
3
4
5
6
7
8
9
2
3
4
255
1)
255
1)
255
1)
1
255
1)
0
2)
0
Tips
255

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120

Table of Contents