Commissioning Tool On Pg/Pc - Siemens SINUMERIK 840D sl Commissioning Manual

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Network configuration characteristics
For the individual, participating components that are connected with the NCU, the following
properties are available for the network configuration.
Table 3-1
Network configuration
Component
TCU/PCU 50.3 and
currently PC/PG for
commissioning of
internal HMI
Factory network
PG/PC for
commissioning of PLC
external HMI
3.4

Commissioning tool on PG/PC

Precondition
If a SINUMERIK 840D sl (internal HMI), consisting of a TCU, NCU 7x0 and SINAMICS S120
drive components is commissioned, the commissioning tool on the PG/PC is required.
To carry out a commissioning with PG/PC with the commissioning tool, the following points
are required:
● Commissioning tool is installed and started on the PG/PC.
● There is an Ethernet connection to NCU (currently X120).
● Since the standard Ethernet IP address is pre-assigned in the commissioning tool for
● If another Ethernet interface is used, e.g. connected to socket X127, then this must be
IBN CNC: NCK, PLC, drive
Commissioning Manual, 07/2007, 6FC5397-2AP10-3BA0
socket
X120
X130
X127
X120 (192.168.214.1), there are no additional requirements.
adapted accordingly in the commissioning tool by selecting HMI > Change standard
address (for example, 192.168.215.1 for socket X127).
Which network?
Ethernet
Ethernet
Ethernet
Requirements for commissioning
3.4 Commissioning tool on PG/PC
IP address
192.168.214.1
Assigned by DHCP
server, for example
10.10.255.200
192.168.215.1
or DHCP Server
Subnet ID
255.255.255.0
255.255.255.248