Planning the RF300 system
4.4 Chemical resistance of the transponders
Substance
Sodium hydroxide solution
Nitric acid
Hydrochloric acid
Sulfuric acid
Tested fuels
FAM testing fluid
acc. to DIN 51 604-A
Toluene
1, 1, 1-Trichloroethane
Xylene
Zinc chloride (saturated)
Explanation of the rating
○○○○
○○○
○○
-
4.4.4

Polycarbonate (PC)

Table 4- 58
Substance
Mineral lubricants
Aliphatic hydrocarbons
Aromatic hydrocarbons
Gasoline
Weak mineral acids
Strong mineral acids
Weak organic acids
Strong organic acids
Oxidizing acids
Weak alkaline solutions
Strong alkaline solutions
Trichloroethylene
94
Resistant
Practically resistant
Conditionally resistant
Less resistant
Not resistant
Chemical resistance - polycarbonate (PPS)
Test conditions
Concentration [%]
Temperature [°C]
30%
10%
10%
10%
10%
30%
Test conditions
Concentration [%]
Temperature [°C]
System Manual, 07/2016, C79000-G8976-C345-0x
Rating
90 ℃
○○○○
23 ℃
○○○○
80 ℃
-
23 ℃
○○○○
80 ℃
○○
23 ℃
○○○○
80 ℃
○○○○
80 ℃
○○
80 ℃
○○○○
80 ℃
○○
75 ℃
○○○○
Rating
○○
○○○○
-
-
○○○○
○○
○○○○
○○
-
-
-
-
SIMATIC RF300