Disconnect UPS Battery

Caution: The UPS battery must be disconnected before you ship the Thor

Equipment Required

The following equipment is user-supplied:

Disconnect Procedure

1. For convenience, the Thor VM1 can
2. If the Thor VM1 remains in the
3. Shutdown the Thor VM1.
4. Place the Thor VM1 face down on a
5. Using a #2 Phillips bit loosen the
6. Locate the small push button located just below the SIM card
7. Press the push button to disconnect the UPS. The UPS battery
8. Reattach the access panel, torquing the M3 screws to 4-5 inch pounds
9. When the Thor VM1 is attached to external power, the UPS battery is
10. Restart the Thor VM1.
Thor VM1 with Microsoft Windows Embedded Standard 2009 User Guide
VM1,
Replace UPS Battery
Torquing tool capable of measuring inch pounds
#2 Phillips screwdriver bit
be removed from the dock, though
it is not necessary.
dock, disconnect the power cable
from the dock.
stable surface.
M3 screws and then remove the
tethered access panel with the SIM
label. This panel is on the right
hand side when the Thor VM1 is face down with the top away from the user.
installation slot.
maintains its charge but is disconnected from the power circuitry of
the Thor VM1.
using a #2 Phillips bit.
automatically reconnected.