Remove Transformer - Maytag 30 Series Service Manual

30 commercial front loading washers
Table of Contents

Advertisement

Arrow On
Flanged End
9.
There are four tabs on each side of the
chemical dispenser that secure the top of
the dispenser to the base. Remove the
top to access the water inlet holes in order
to clean any mineral or chemical build-up,
which could slow the incoming water.
Fabric
Softener
Bleach
Detergent
View Of Under Side Of
Chemical Dispenser Top
Arrow
On Tub
Upper
Cold Valve
Number 2
Hot Valve
Lower
Number 1
Cold Valve
Number 3

reMOve TranSFOrMer

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug washer or disconnect power.
2.
Turn off the water supply to the washer.
3.
Lift the washer top (See page 4-3).
4.
The transformer for the UIC is attached to
the control panel bracket, on the right end
near the CCU.
5.
Disconnect the wire harness connector from
the transformer to the CCU and cut wire tie.
6.
Remove two 1/4" hex head screws that
secure the transformer to the control panel
bracket and remove the transformer.
Transformer Primary
Winding Connector
Wire Tie
Placement
nOTe: Remove and replace rubber screw
tip covers and wire tie when servicing
transformer.
4-15
CCU
Rubber
Screw Tip
Covers
UIC Transformer
On Other Side