Remove Rfi Line Filter - Maytag 30 Series Service Manual

30 commercial front loading washers
Table of Contents

Advertisement

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug washer or disconnect power.
2.
Turn off the water supply to the washer.
3.
Lift the washer top (See page 4-3).
RFI Line
Filter
4.
Remove the T-20 1/4" hex head screw. (See
first picture in next column)
5.
Slide the RFI line filter to the left to release
the tabs in the slots.
6.
Power goes into the RFI line filter through
the black (hot) wire and white (neutral) wire
connectors. Power goes out to the CCU
through the pink wires.

reMOve rFi Line FiLTer

4-12
T-20 Screw
RFI Line Filter
7.
Press The locking tab and remove the
connector for the pink wires.
8.
Pull the black and white wire connectors off
their spade terminals.
nOTe: Problems can occur with this washer
if the AC power is connected with reverse
polarity. When properly installed the White
(neutral) wire connector should be toward the
front of the washer as viewed from the RFI
filters installed orientation.
To test for proper polarity, power must be
reconnected to the washer, test between the
white (neutral) wire connector and any chassis
ground connection with a volt meter. If the
polarity is correct there should be no voltage
present. Disconnect the washer from the
power before proceeding.
4 Tabs In Slots
Pink Wires
Out To CCU
White (Neutral)
Black (Hot)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mhn30pdaww0Mhn30pdaxw0Mhp30praww0Mhn30praww0