Remove Power Supply Cord - Maytag 30 Series Service Manual

30 commercial front loading washers
Table of Contents

Advertisement

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug washer or disconnect power.
2.
Turn off the water supply to the washer.
3.
Lift the washer top (See page 4-3).
4.
Remove the screw from the green ground
wire. (See first picture in next column)
5.
Pull the connectors with white and black
wires from the RFI line filter terminals.
RFI Line
6.
Pull the washer away from the wall far
enough to access the power supply cord on
the rear panel.
7.
Remove the one 1/4" hex head screw that
secures the power supply cord strain relief
to the rear panel of the washer.

reMOve POWer SuPPLY COrD

Filter
Ground Wire Screw
8.
Push the wire connectors out the rear panel
of the washer.
1/4" Hex
Head Screw
4-13
2 Wire
Connectors