reMOve MeTerCaSe (MODeL MHn30PD)

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug washer or disconnect power.
2.
Remove the coin box.
3.
Remove two 1/2" hex head bolts below the
coin box in the front of the coin vault area.
Head Bolts
1/2" Hex
4.
Remove the service access door.
5.
Remove two 1/2" hex head bolts from inside
the service access area at the base of the
metercase.
6.
Remove the metercase from the washer
and the pad that is between the metercase
and the washer top.
nOTe: When reinstalling the metercase
mounting bolts, make sure the bolts are
tightened securely to avoid excess noise
and vibration. Torque specification is 12-15
foot pounds.
nOTe: In cases where the coin box does
not fit snug in the coin vault, it can add
to the noise of a vibrating and shaking
metercase assembly. Two foam pads can
be installed on the front sides inside the coin
vault. They will serve to snug the coin box
within the coin vault.
Foam Pad On
Each Side