Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug washer or disconnect power.
2.
Turn off the water supply to the washer.
3.
Lift the washer top (See page 4-3).
Pressure
Switch
4.
Disconnect the wire harness by pressing the
locking tabs and pulling the wire harness off
the pressure switch.
reMOve PreSSure SWiTCH
5.
Rotate the pressure switch 45 degrees and
pull the rectangular tab out of the slot in the
top of the washer side panel.
Wire
Harness
Air Hose
6.
Disconnect the air hose on the bottom of the
pressure switch, there is no clamp, just a
pressure fit.
nOTe: Hose should be snug to avoid air
leaks.
Key
4-11
Pressure
Switch
Slot