reMOve LOW vOLTaGe TraNSFOrMer

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Remove the control panel (see page 4-1).
2.
Disconnect the primary winding locking
Molex plug. Use a flat blade screwdriver to
release the locking tab and disconnect the
plug.
3.
Disconnect the secondary winding wire
connector that is attached to the middle of
the control board.
Primary Winding
Locking Molex Plug
4.
Remove the two - 5/16 inch hex head
screws that secure the low voltage
transformer to the washer top panel.
5/16 inch hex
head screws
5.
Remove the transformer.
4-11