Remove Air Gap Damper - Maytag 30 Series Service Manual

30 commercial front loading washers
Table of Contents

Advertisement

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug washer or disconnect power.
2.
Turn off the water supply to the washer.
3.
Remove the lower service panel
(See page 4-21)
or
Remove the rear panel (See page 4-28).
4.
Use a flat blade screwdriver to release one
of the locking tabs and turn the upper half of
the damper body slightly to hold that locking
tab unlocked.
5.
Reach around to the other side and release
the other locking tab.
6.
Turn the upper half of the damper body 90
degrees and pull the tab out of the slot in
the tub.
1/4 Turn
To Unlock
Damper

reMOve air GaP DaMPer

Locking Tab
Both Sides
4-34
7.
The damper is attached to the base in the
same way, with 2 locking tabs.
1/4 Turn
To Unlock
Damper
Locking Tab
Both Sides
8.
To separate the two halves of an air gap
damper, Disconnect either the bottom or the
top of the air gap damper from the washer.
Slide the two halves of the air gap damper
apart to separate them.
nOTe: In the base there is a moulded stop
that will keep the damper from rotating in
the wrong direction.
TeCH TiP: When removing the tub, the air
gap dampers simply separate when the tub
assembly is pulled up out of the washer.
TeCH TiP: When removing the left rear air
gap damper, use a hammer and a punch to
level the rear most raised tab, on the base
of the washer.
Rear Most
Raised Tab

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mhn30pdaww0Mhn30pdaxw0Mhp30praww0Mhn30praww0

Table of Contents