Outside Line/Outgoing Number
The SP sets the number that switches to PSTN for the outside connection for Cumin-M in a
system that employs a PBX (internal line).
• If the execution of SP5816 151 has succeeded and Cumin-M has connected to the
external line, this SP display is completely blank.
154
• If Cumin-M has connected to an internal line, then the number of the connection to
the external line is displayed.
• If Cumin-M has connected to an external line, a comma is displayed with the number.
The comma is inserted for a 2 sec. pause.
• The number setting for the external line can be entered manually (including commas).
Dial Up User Name
Use this SP to set a user name for access to remote dial up. Follow these rules when setting
a user name:
156
• Name length: Up to 32 characters
• Spaces and # allowed but the entire entry must be enclosed by double quotation
marks (").
Dial Up Password
Use this SP to set a password for access to remote dial up. Follow these rules when setting
a user name:
157
• Name length: Up to 32 characters
• Spaces and # allowed but the entire entry must be enclosed by double quotation
marks (").
Local Phone Number
Use this SP to set the telephone number of the line where Cumin-M is connected. This number
161
is transmitted to and used by the Call Center to return calls.
Limit: 24 numbers (numbers only)
Connection Timing Adjustment: Incoming
When the Call Center calls out to a Cumin-M modem, it sends a repeating ID tone (*#1#).
This SP sets the line remains open to send these ID tones after the number of the Cumin-M
162
modem is dialed up and connected.
[0 to 24 / 1 / 1 /step]
The actual amount of time is this setting x 2 sec. For example, if you set "2" the line will
remain open for 4 sec.