006 Absolute Humidity
007 Temp Threshold M
008 RH Threshold M
009 AH Threshold M
010 Temp Threshold S
011 RH Threshold S
012 AH Threshold S
013 Non-use Time
2015
[Charge AC Adj: Result]
001 Bk
002 M
003 C
004 Y
[Color Registration Correction] FA
These values are the parameters for the automatic line position adjustment and are adjusted
2101
at the factory. However, you must input a value for SP2101-001 after replacing the laser
optics housing unit. For details, see "Laser Optics Housing Unit" in the "Replacement and
Adjustment" section. The value should be provided with the new laser optics housing unit.
001 Main Dot: Bk
002 Main Dot: M
003 Main Dot: C
004 Main Dot: Y
005 Sub Line: Bk
006 Sub Line: M
007 Sub Line: C
008 Sub Line: Y
*ENG
[0 to 99 / 12 / 1 g/m
*ENG
[0 to 99 / 10 / 1 deg/step]
*ENG
[0 to 99 / 50 / 1 %RH/step]
*ENG
[0 to 99 / 6 / 1 g/m
*ENG
[0 to 20 / 1 / 0.1 deg/step]
*ENG
[0 to 50 / 5 / 1 %RH/step]
*ENG
[0 to 20 / 1 / 0.1 g/m
*ENG
[0 to 1440 / 360 / 10 min/step]
*ENG
*ENG
[0 to 9 / 0 / 1 /step]
*ENG
*ENG
*ENG
*ENG
[–512 to 511 / 0 / 1 dot/step]
*ENG
*ENG
*ENG
*ENG
[–16384 to 16383 / 0 / 1 line/step]
*ENG
*ENG
System Service Mode
3
/step]
3
/step]
3
/step]
8
173