4. Replacement and Adjustment
2. Remove the left cover and harness cover bracket (see the following "Removing the old laser optics
housing unit")
4
3. Disconnect the harness [A] of the skew correction motor.
4. Do steps 1 to 7 of "Before removing the old laser optics housing unit".
5. Connect the harness [A] and reinstall the harness bracket and left cover.
6. Plug in and turn on the main power switch.
Removing the old laser optics housing unit
1. Left cover [A] ( x 6)