Ends Temp. 4: –226
Specifies the temperature correction for the heating roller (ends) when the paper width is less
017
than 226 mm.
The start time of this SP can be adjusted with SP1116-021.
Control Time 1: 226–
Specifies the start time of the temperature correction that is set with SP1116-010 and -011.
018
The temperature correction is added when the time specified with this SP has passed after
feeding the paper.
Control Time 2: 226–
Specifies the start time of the temperature correction that is set with SP1116-012 and -013.
019
The temperature correction is added when the time specified with this SP has passed after
feeding the paper.
Control Time 3: –226
Specifies the start time of the temperature correction that is set with SP1116-014 and -015.
020
The temperature correction is added when the time specified with this SP has passed after
feeding the paper.
Control Time 4: –226
Specifies the start time of the temperature correction that is set with SP1116-016 and -017.
021
The temperature correction is added when the time specified with this SP has passed after
feeding the paper.
022 M-Thick 1: Center Temp >=226
023 M-Thick 1: Ends Temp. >=226
024 M-Thick 2: Center Temp >=226
025 M-Thick 2: Ends Temp. >=226
026 M-Thick 3: Center Temp >=226
027 M-Thick 3: Ends Temp. >=226
028 M-Thick 4: Center Temp >=226
029 M-Thick 4: Ends Temp. >=226
ENG
[-10 to 10 / 0 / 1 deg/step]
ENG
[0 to 250 / 60 / 1 sec/step]
ENG
[0 to 250 / 0 / 1 sec/step]
ENG
[0 to 250 / 60 / 1 sec/step]
ENG
[0 to 250 / 0 / 1 sec/step]
ENG
[-10 to 10 / 0 / 1 deg/step]
ENG
ENG
[-10 to 10 / 0 / 1 deg/step]
ENG
ENG
[-10 to 10 / 0 / 1 deg/step]
ENG
[-10 to 10 / 5 / 1 deg/step]
ENG
[-10 to 10 / 0 / 1 deg/step]
ENG