Low Temp. Correction
Specifies the temperature correction for the heating roller. When the low temperature
003
condition (specified with SP1112-001) is detected, the value of this SP is added to the
heating roller temperature.
High Temp. Correction
Specifies the temperature correction for the heating roller. When the high temperature
004
condition (specified with SP1112-002) is detected, the value of this SP is subtracted from
the heating roller temperature.
005 Low Temp. Correction: Paper Feed *ENG
High Temp. Correction: Paper
006
Feed
1113
[Stand-by Time]
001
After Ready
After Recovery
003
Specifies the time for keeping the target temperature after recovery (SP1105-083) without
any jobs.
004
After Job
005
PressureTemp: After Ready
006
Pressure Temp: After Job
008
ON/OFF Time Switch
1115
[Stand-by Idling]
Interval
001
Specifies the interval between idling during stand-by mode.
This idling during the stand-by mode prevents the roller deformation.
Idling Time
002
Specifies the length of each idling operation during stand-by mode.
003 Idling Speed
*ENG
[0 to 15 / 5 / 1 deg/step]
*ENG
[0 to 15 / 5 / 1 deg/step]
[0 to 15 / 6.5 / 0.1 deg/step]
*ENG
[0 to 15 / 5 / 1 deg/step]
*ENG
[0 to 60 / 20 / 1 sec/step]
*ENG
[0 to 60 / 10 / 1 sec/step]
*ENG
[0 to 60 / 10 / 1 sec/step]
*ENG
[0 to 160 / 100 / 1 deg/step]
*ENG
*ENG
[0 to 999 / 300 / 1 sec/step]
*ENG
[1 to 240 / 60 / 1 min/step]
*ENG
[1 to 60 / 2 / 0.1 sec/step]
*ENG
[0 to 1 / 0 / 1 mm/sec/step]