MS165
7.2
Exhaust port (air flow)
Tapped holes PT3/8 with pipe plug
Connector for the external axis
(Power cable):
JL05-2A18-1SC (socket connector with cap).
Prepare pin connector: JL05-6A18-1P.
Connector for the external axis (Encoder cable):
JL05-2A20-29SC(socket connector with cap).
Prepare pin connector: JL05-6A20-29P.
Connector for internal
I/O wiring harness (Casing):
JL05-2A24-28SC (socket connector with cap).
Prepare pin connector: JL05-6A24-28P.
7
System Application

7.2 Internal User I/O Wiring Harness and Air Line

Internal User I/O Wiring Harness and Air Line
The internal user I/O wires (0.75 mm
cables for the external axis (2.0 mm
2
mm
x 6 cables), and an air line are used in the manipulator for the drives
of the peripheral devices mounted on the upper arm as shown in fig. 7-2
"Connectors for Internal User I/O Wiring Harness and Air Line" .
The connector pins, and the terminals are assigned as shown in fig. 7-2
and fig. 7-3 "Details of the Connector Pin Numbers" . Wiring must be
performed by user.
The allowable current for internal user
I/O wiring harness
The maximum pressure for the air line 490 kPa (5 kgf/cm
Fig. 7-2: Connectors for Internal User I/O Wiring Harness and Air Line
Key positions
7-2
2
x 11 wires, 0.5 mm
2
x 4 cables, 0.75 mm
16.1A or less / wire. (2.0 mm
5.0A or less / wire. (0.75 mm
3.5A or less / wire. (0.5 mm
2.3A or less / wire. (0.2 mm
2
) or less
(The air line inside diameter: 8.0mm)
Connector for internal user
I/O wiring harness (Base):
JL05-2A24-28PC (pin connector with cap).
Prepare socket connector: JL05-6A24-28S.
Air inlet (air flow)
Tapped holes PT3/8
with pipe plug
View A
A
HW1482308
167109-1CD
2
x 12 wires), the
2
x 2 cables, 0.2
2
)
2
)
2
)
2
)
54 of 100