Notes For Maintenance; Battery Pack Connection - YASKAWA MOTOMAN-MS165 Instructions Manual

Table of Contents

Advertisement

167109-1CD
MS165
9.5

9.5.1 Battery Pack Connection

9
Maintenance and Inspection

9.5 Notes for Maintenance

Notes for Maintenance
When performing maintenance such as replacement of a
wire harness in the manipulator, the encoder connector may
be necessary to be removed. In this case, be sure to con-
nect the battery pack to the battery backup connector
before removing the encoder connector.
NOTE
Removing the encoder connector without connecting the
battery pack leads to disappearance of the encoder
absolute data.
For the battery pack connection, refer to fig. 9-14 "Battery
Pack Connection" .
The connectors (crimped contact-pin) for the battery backup are installed
at the end point of the motors (BAT and OBT are marked). Connect the
battery packs according to the following procedure.
1. Removed the cap attached to the battery backup connector of the
motors.
2. Connect the battery packs (HW9470932-A) with the battery backup
connectors (BAT and OBT are marked) located at the end point of the
cables for the encoder. (Under this condition, remove the encoder
connector and carry out the maintenance checks).
3. Confirm all connectors connected after the maintenance check, and
remove the battery packs. Install the caps attached to the battery
backup connectors of the motors.
NOTE
Do not remove the battery pack in the connector base.
9-23
HW1482308
84 of 100

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents