10.BCD DATA OUTPUT(OPTION)

10-2. Logic Change

Select the logic of output signals with pin No. 28.

10-3. BCD Data Hold

The BCD data output signal is held. Switching is carried out by pin No. 27.

10-4. Equivalent Circuit

・Output
The signal output circuit is operated through a TTL open collector.
76
When COM and pin No. 28 are open: negative logic
When they are short-circuited: positive logic
When COM and pin No. 27 are open: hold cancel
When they are short-circuited: hold on
Vcc
+5V
Vceo=30V(max)
Ic =30mA (max)
● Internal transistor status
Output data
Negative
0
OFF
1
ON
F370
Inside
Outside
COM
● Output pin level
Positive
Output data
ON
0
OFF
1
Through logic switching ( pin28)
Vext
Negative
Positive