Options - Unipulse F370 Operation Manual

Digital indicator
Table of Contents

Advertisement

Comparison functions
Calibration value selection

21-3. Options

BCD data output
RS-232C communication interface
RS-485 communication interface
D/A converter
HI-HI limit
LO-LO limit
HI limit
LO limit
Four calibration values can be stored in memory and
switched.
Open-collector output
Output rate
Can be selected from 1 time/sec., 10 times/sec., 100 times/sec.
and 1000 times/sec.
Start/stop system
Baud rate: 1200bps - 19200bps
Communication conditions are the same as RS-232C.
Voltage output
-10 - 10V
Current output
4 - 20mA
Zero output and full scale output can be digitally adjusted.
21.SPECIFICATIONS
External output
HH
LL
OK
HI
LO
109

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents