Alarm Mode - Unipulse F370 Operation Manual

Digital indicator
Table of Contents

Advertisement

6-6. Alarm Mode

The comparison target of the HI-HI limit and LO-LO limit set values can be changed
from "hold value" to "real-time value". By this function, whether or not the indicated
value becomes abnormal during hold can be monitored.
Unavailable : Comparison operation is performed with hold values.
Available
How to set
Setting call
: Comparison operation is performed with real-time values.
Alarm mode unavailable
HH
HI
Alarm mode available
HH
HI
When the comparison output mode is "mode 0: HI limit operation for
all of HI-HI limit/HI limit/LO limit/ LO-LO limit", the alarm mode
operation can only be performed with the HI-HI limit.
In a like manner, when the mode is "mode 4: LO limit operation for all
of HI-HI limit/HI limit/LO limit/LO-LO limit", the alarm mode operation
can only be performed with the low-low limit.
Comparison setting
6.COMPARISON FUNCTIONS
Real-time values
Hold values
OFF
OFF
Page 2
HI-HI Limit (HH)
HI Limit (HI)
OFF
ON
43