Technical Support - SINTERIT Lisa Pro User Manual

Hide thumbs Also See for Lisa Pro:
Table of Contents

Advertisement

1. If the nitrogen pressure becomes too high or too low, an ​ i ntermittent sound signal​ is
activated.
2. If the concentration of oxygen in the printer's surroundings is too low, a ​ c ontinuous
sound signal​ is activated.
3. If the oxygen level in the printer's surroundings drops below 19%, the device ​ s tops
printing​ and displays a message to close the nitrogen supply.
4. If the nitrogen pressure is too low, connect a proper nitrogen supply or the printing ​ w ill
stop in 3 minutes.
5. If the nitrogen pressure is too high, a ​ n otification is displayed​ .
WARNING!
The built-in oxygen level detector is not a certified device and the signal
cannot be treated as the only warning. Keep the LISA PRO printer and the
nitrogen bottle in well ventilated rooms.
If you hear an alert, open the windows/ventilate the room and leave the room.
If you feel any suspicious symptoms, immediately leave the room and go
outside/to a well ventilated room.
G. Technical support
The latest information, technical support, and versions of the manual are available in the
Support tab of the Sinterit Sp.z.o.o. company website or by contacting us through email:
contact@sinterit.com​
The list of distributors and technical support in specific countries can be found at
www.sinterit.com​
 
 
44 
o r phone: ​
+ 48 570 967 860​
.
.
Sinterit Lisa PRO USER
MANUAL 

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Lisa Pro and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents