1. If the nitrogen pressure becomes too high or too low, an i ntermittent sound signal is
activated.
2. If the concentration of oxygen in the printer's surroundings is too low, a c ontinuous
sound signal is activated.
3. If the oxygen level in the printer's surroundings drops below 19%, the device s tops
printing and displays a message to close the nitrogen supply.
4. If the nitrogen pressure is too low, connect a proper nitrogen supply or the printing w ill
stop in 3 minutes.
5. If the nitrogen pressure is too high, a n otification is displayed .
WARNING!
The built-in oxygen level detector is not a certified device and the signal
cannot be treated as the only warning. Keep the LISA PRO printer and the
nitrogen bottle in well ventilated rooms.
If you hear an alert, open the windows/ventilate the room and leave the room.
If you feel any suspicious symptoms, immediately leave the room and go
outside/to a well ventilated room.